Skip to main content

Separation & dewatering equipment for Canada and the United States since 2014Call 604.484.4516 · Toll free (888) 588-0480

IIoT Gateway: DAF Process and Chemical Dosing Controller

A DAF process and chemical dosing controller: every chemical measured, controlled and verified from one 7-inch touchscreen.

The Archer IIoT Gateway is a purpose-built controller for dissolved air flotation and chemical treatment systems. It combines multi-pump chemical metering, closed-loop dosing, sensor and pump calibration and secure cloud connectivity in one panel-mount unit, and replaces open-loop dosing and manually tuned loops with measured, verified, self-tuning control.

Archer IIoT Gateway 7-inch touchscreen faceplate showing the pump control screen

Why a DAF needs one

Most DAF systems run open-loop. Polymer is overfed to be safe, pH loops hunt around neutral, and a dosing problem only shows when the effluent goes out of specification.

The Gateway closes every loop: it measures what is in the water, doses each chemical against it, and checks what was actually delivered with a flowmeter on every chemical line.

Measure, control, verify

Measure

pH, ORP, turbidity, TSS, conductivity and streaming current over Modbus RTU, Modbus TCP/IP, EtherNet/IP or 4–20 mA, with automated probe cleaning and guided calibration.

Control

Up to three self-tuning PID loops drive up to four metering pumps, with adaptive linearised pH control and TSS feedforward and feedback dosing.

Verify

A flowmeter on each chemical line compares the commanded dose with the delivered dose, in ppm, on screen at all times.

Report

An on-board historian logs every loop; secure MQTT streaming puts live values, trends and alarms on a cloud dashboard.

Control capabilities

Stable pH, one tune

Adaptive linearised pH control holds steady across the full titration curve, for acid and caustic neutralisation, without retuning when the feed chemistry changes.

Polymer dosed to the water

TSS-based polymer control: feedforward on the influent solids load with feedback trim on underflow TSS, using one or two TSS probes. See TSS polymer control.

Coagulant optimisation

Streaming current analyser support for charge-based coagulant dosing against an operator setpoint.

Tuning without a specialist

Built-in autotune characterises each loop and suggests parameters for the operator to review, so loops are commissioned in hours.

Calibration built in

Guided calibration for dosing pumps and every connected sensor, plus solenoid-driven air or water probe cleaning that reduces drift in fouling streams.

Safe in manual

AUTO, MAN, fixed-dose ppm and dose ON/OFF per pump, with bumpless transfer: an operator can take any pump from the screen at any time.

TSS control block for a DAF: feedforward on feed TSS times flow, feedback trim on underflow TSS, and the pump curve to pump speed
The TSS control block used for polymer: feedforward from the solids load, a bounded feedback trim that holds the DAF in the trough of the dose curve, and the pump characteristic that turns the dose into a pump speed.

Specifications

Controller64-bit quad-core ARM industrial compute module, 4 GB RAM (8 GB optional), industrial eMMC, hardened embedded Linux; fanless, no moving parts
Display7-inch industrial TFT, 1024 × 600, projected-capacitive touch usable with wet fingers and gloves; panel-mount faceplate
Pump channelsUp to 4 metering pumps: 4–20 mA speed reference or pulse output, run/enable relay, run and fault feedback per pump
Control loopsUp to 3 independent PID loops, direct or reverse acting, with autotune
Sensor interfacesModbus RTU (RS-485), Modbus TCP/IP, EtherNet/IP, isolated 4–20 mA / 0–10 V; mixed configurations supported
Inputs and outputsDry-contact status and pulse inputs; 4–20 mA and relay outputs; dedicated solenoid outputs for probe cleaning; remote I/O expansion over Modbus TCP
CommunicationsMQTT over TLS to the cloud dashboard; on-board historian with trend screens and data export
Power and environment24 VDC (18–30 VDC), about 15 W; 0 to 50 °C; IP65 front panel

Preliminary. Specifications are typical and subject to change; final configuration is confirmed in Archer’s scope of supply.

Applications

DAF, municipal and industrialFood and beverage wastewaterMeat, poultry and renderingpH neutralisationPolymer make-down and dosing skidsCentrifuge feed conditioningCoagulant optimisationRetrofit of manual dosing

Configure a Gateway for your plant

Tell us the DAF or dosing duty, the chemicals, the pumps and the instruments already fitted, and we will configure and quote a Gateway for it. Existing instruments can usually be reused.

Datasheet

Hardware, instruments and communications in detail.

Download the datasheet (PDF)

Online questionnaire

Fill in the scoping questions online instead of on paper.

Start the questionnaire

Related pages

Talk to an engineer

Talk to an engineer about your separation challenge

Contact us today with all your separation and dewatering challenges.