Lower Mainland BC Plastics Recycling Plant: DAF Case Study

A complete dissolved air flotation system – DAF unit, flocculator, polymer make-down and chemical dosing skids – treats the wash water of a plastics recycling plant in the Lower Mainland, BC.

Stainless steel DAF unit with pipe flocculator treating plastics recycling wash water
2021Commissioned
13.6 m³/haverage wash water flow
3,813 mg/Linfluent TSS (lab test)
≤ 300 mg/Lguaranteed effluent TSS

The application

The client, in the Lower Mainland of BC, recycles post-consumer plastics. Washing the shredded plastic produces a wastewater loaded with suspended solids, grease and dissolved organics – the lab sample used for design had 3,813 mg/L TSS and 11,450 mg/L COD.

Archer supplied a complete physico-chemical treatment line built around an Ekoton DAF with lamella plates. The wash water is conditioned in a pipe flocculator with pH control, coagulant and polymer, then the floated solids are scraped off the top while heavy solids settle and are drawn off from the bottom.

Instead of an air compressor and saturator, a multiphase EDUR recirculation pump makes the micro-bubbles, which keeps the system compact and simple to run.

What Archer supplied

  • Ekoton FT-15L dissolved air flotation unit in 304 stainless steel with FRP lamella plates, scum scrapers on a stainless chain and motorized bottom-sludge valves
  • Ekoton KF-15 pipe flocculator in Sch 80 PVC with static mixers and injection points for coagulant, pH adjustment and polymer
  • EDUR multiphase recirculation pump (4 kW, 6 bar, 10 m³/h) for micro-bubble generation, with valves, gauge, flowmeter and pressure switch
  • Archer polymer make-down system with 600 L two-compartment HDPE tank and SYDEX progressive cavity feed pump
  • Pre-piped chemical dosing skids for acid, base and coagulant, each with metering pump, calibration column and turbine flowmeter
  • Victor self-priming feed and effluent pumps (two duty, one shared standby) and an air-operated diaphragm pump for thickened sludge
  • Endress+Hauser pH, turbidity and flow instruments, and a CSA-certified control panel with PLC and 15″ touch screen

Design basis

WastewaterPlastic recycling wash water, screened
Flow60 US gpm average (13.63 m³/h), up to 70 US gpm (15.89 m³/h)
Influent TSS3,813 mg/L average (lab test)
Influent FOG / BOD₅ / COD420 / 3,630 / 11,450 mg/L
Operation8 h/day, 5 days/week
GuaranteeDAF effluent TSS ≤ 300 mg/L

Design figures from Archer proposal 9121601 (Section 4, Rev 8).

Two pre-piped chemical dosing skids on HDPE backplanes for pH and coagulant dosing
Dosing skids. Acid, base and coagulant skids, pre-piped on HDPE backplanes.
Floated solids blanket on the surface of the DAF unit
Float. The floated solids blanket ahead of the scrapers.
Pipe flocculator manifold under the DAF unit
Flocculator. Sch 80 PVC pipe flocculator with chemical injection points.
Lamella plates inside the DAF unit
Lamella plates. FRP lamella plates increase the clarification area.